For more detail information please call us on 021-29628607 or email to sales1@yamata.co.id
Press B-D-C Monitoring and Recording Device NEW SELBER VXRM-7302 / RM-7304
Specifications Device NEW SELBER VXRM-7302 / RM-7304
Name | NEW SELBER VX |
Model | RM-7302J (2ch)/RM-7304J (4ch) *For overseas, some models are different. |
Detection resolution | 0.1μm *For overseas: 0.5μm |
Monitoring method | Previous value comparison/Standard value monitoring |
Input | 3 points, non-voltage NPN open collector output (Drive current 15mA or more) or contact input |
Timing input Non-voltage NPN or PNP open collector output or contact input | |
Output | 2 points, relay contact (C contact) NC-C-NO AC250V 2A Max. (Resistive load) |
Power supply for timing signal DC12V 250mA Max. | |
Maximum number of rotations that can be monitored | 4500spm |
Operating Temperature Limit | -5-58℃ (No Condensation) |
Ambient atmosphere when used | Free from corrosive gas and dust |
Power supply | AC100V-240V 50/60Hz |
Weight | Main Unit: Approx. 3.5kg Mounting angle: Approx. 1.7kg |
External Dimensions | 260 (W) x 170 (H) x 136 (D) mm (excluding terminal block and other protrusions) |
Display | Color TFT LCD (7.5-inch) Number of dots Horizontal 640 x Vertical 480 Backlight life 50,000 hours (Typ.) |
*The specifications and the contents described in this instruction manual are subject to change without prior notice.
- Monitoring method (standard value, previous value) can be selected
- Resolution 0.1μm (Overseas: previous value 0.1μm, standard value 0.5μm)
- Can record 8 shots waveform data before error detection
- Able to simultaneously monitor slug inside die and die height variation due to thermal expansion. Ideal for improving product accuracy.